Product Description
The continuous curing tunnel sits on the overhead conveyor line; parts pass through at constant speed to dry off water after pretreatment or to cure powder, liquid or electrophoretic (ED) coatings. The gas burner fires in a separate combustion chamber, and recirculation fans deliver hot air into the tunnel through distribution ducts, keeping the temperature even along its length.
Features:
- Automatic gas burner imported from Europe, complete with valve train, pressure regulator and gas safety devices.
- U-shaped, Π-shaped or straight tunnel; air curtains at the entry and exit reduce heat loss.
- Automatic temperature control panel (Omron controllers) for the recirculation fans and roof exhaust fan; whole-system emergency stop if a recirculation fan fails.
- Exhaust can be connected to a gas treatment tower (activated carbon) to meet environmental standards.
| Parameter | Reference value |
|---|
| Fuel | LPG or natural gas |
|---|
| Temperature control range | 50–220 °C (water drying, liquid paint, ED, powder) |
|---|
| Roof exhaust fan | Heat-resistant up to 250 °C |
|---|
| Conveying | Overhead chain conveyor, inverter speed control |
|---|
| Insulation | 100–150 mm glass-wool panels |
|---|
| Size, power | Designed to output (m²/h or hangers/min) and curing time |
|---|

Reference values; dimensions and capacity are designed to order.
Consultation & quotation: Hotline 0913203999 - 0913537888 - 0889999802 · Email info@kieuan.vn